500KW Εγκαταστάσεις Αποτέφρωσης

 

GOODS & DESCRIPTIONS                                                          QUANTITY

 

1. Steam turbine, generator & auxiliary machines                   1 UNIT

1.1 Steam turbine Condensing                                                    1 Set

•    Steam turbine model N0.5-0.98 Power 500KW
•    Inlet pressure 0.98MPa
•    Inlet temperature 300degC
•    Inlet steam volume 2.9T/h
•    Steam consumption rate 5.8kg/kw.h
•    Speed 6500~1500rpm
•    Exhaust pressure 0.5MPa
•    Layout single-deck
•    Rotor structure 7P
•    Noise level of steam turbine dB ≤80

1. 2 Generator                                                                               1 Set

Rated power 500KW Rated Voltage 400V Frequency 50HZ Speed 1500rpm

1.3 Steam turbine auxiliary machines including: Speed reducer, auxiliary equipment’s

 

2. Boiler                                                                                          1 UNIT

•    Rated evaporation 4T/h.
•    Working pressure 1.25MPa
•    Steam temperature 330degC
•    Heating area 212.9m2
•    Active grate area 4.8 m2
•    Combustion mode : The chain grate firing
•    Fuel Biomass Design thermal efficiency 79.56%
•    Dust emission concentration 81mg/Nm3 (after dedusting)
•    Upper body transport weight 28.8t Transportation size 7.0M*2.64M*3.522M